What exactly is the difference between a surge protector and a fuse? Can a fuse protect the electronic devices from lightning instead of surge protector?
10.06.2025 02:23

This one hit behind the barn.
Fuses, on their own, then operate much slower than the MOV variable resistance, during the lightning strike.
He then asserts :
What's your favorite stupid joke?
A circuit breaker is similar, but is resettable.
It’s been three xxx five werks, and there has been no response to my follow on query on his Commment to my answer.
Would individual surge supressors have save this equipment? most likely, since the surge supressor would take the jolt instead of the electronic components.
Charting the Global Economy: US GDP Falls on Larger Trade Hit - Bloomberg
P = e* I, so since I is 16 amps, then the voltage dropped is 1/16 volt or 0.0650 volts.
But… the neutral is now “floating” because of the 1 ohm resistance.
but this device (an Inductor) … impedes the rapid changes in the current.
‘King of the Hill’ voice actor Jonathan Joss is fatally shot in Texas - The Washington Post
There are three different concepts here that are getting confused.
This is where this question deviates from being a 'generic' question, and becomes more specific.
One is “what exactly is in a ‘surge protector’ ? ”
Could This Diet Be the Key to Preventing Alzheimer's and Dementia? - bestlifeonline.com
There is no harm in having the surge suppressor along with the fuse in the circuit. The fuse will not open up until the current melts the link. This will take time, and in the interim, that jolt will get transmitted into the power supplies.
The third is lightning and “how it gets conducted into a home.”
Because the load is inductive, the current lags the voltage.(by a bit).
Facial Stimulation Clears Brain Waste and Boosts Aging Minds - Neuroscience News
This is a photo where a lightning bolt took out a home's complete mains distribution box, and a lot of electronic gear as well.
So combined with a device called a MOV or Metal-oxide-resistor, then forms the 3rd part of a “surge suppressor “.
This is the picture of an electronic coil of wire wound around a core of magnetic material.
How do I build rapport with anybody?
But during the surge, the fuse will not blow if it is a longer duration and lower value )10 to 50%).
a photo is worth a thousand words.
This device then solves the entire problem.
Six killed by Israeli gunfire near Gaza aid site, Hamas officials say - BBC
The MOV will conduct when the voltage exceeds 50% of line voltage.
what exactly is a ‘surge’ protector?
“ A fuse is a device which protects the (circuit) against overload and short circuit.”
“ A surge suppressor is the one which is connected at the input supply so that when there is a sudden change voltage it bypasses thereby protecting the (circuit) and electronic components”
but I think this circuit , shows a few more pieces.
2024–10–11 [Bobby Sanchez Bobby Sanchez ].
Chime, last valued at $25B, aims for $11B in upcoming IPO - TechCrunch
so, what happens?
If the nominal power is 4,000 watts then the current at 230volts is 16 amps.
2024–10–14 [Omar Gharbi Omar Gharbi ]
nine
Once the voltage goes over 0.0650 volts, then this fact can be used to amplify the difference, and turn the circuit breaker off , furthur down the line. Essentially that is what a RCD/GFCI does, it compares the incoming current, to the outgoing current, and if the difference between the two currents is over 5mA, then it trips the circuit breaker.
Can the fuse protect the electronic devices from lightning instead of a surge protector.
Why should you never do drugs? Will this story absolutely shock you?
2024–10–11 [Victor Olarewsju Victor Olarewaju ]
For this case there are devices called Metal oxide varistors (MOV).
This is where the MOV conducts again, and dissipated the energy.
At least they know the answer if they wanted it.
It also is a device that limits the change in current flow.
So, the voltage could go up to 500 volts, and the fuse will not open up.
Rihanna’s Father, Ronald Fenty, Dies at 70: Report - Billboard
At the secondary, it is 1000 times less.)turns ratio). If it gets hit with a 100,000 volt bolt of lightning then the voltage arrestors conduct and clamp the voltage down to line voltage, ( but a small amount leaks down the line). This is the problem.
2024–10–10[John johnson John Johnson ]
2024–10–00 [ Ammar Mahdi ] Ammar Mahdi
The other is “what does a “fuse” do?”
2024–09–27 [ Mohan Rajaratnam Mohan Rajaratnam ] . Thinks you can get free electricity from nothing : Mohan Rajaratnam's answer to Is it possible to generate free electricity at home using a magnet or other low-cost methods? If so, how does it work?
An AC voltage/ current source, and an ac inductive load.
He then describes Rainy Season and Lightning.
This is an electronic circuit designed to clamp voltages so that the Voltage Potential that appears at the outlet is never going to exceed the nominal value.
This is 'the assistant's answer'
In schematic diagrams this is the symbol for a fuse:
What does a fuse do?
First Sentence:
(There is no concept of polarity, in the loop because the current changes direction 100 to 120 times a second (power frequency).
eight
Lightning arrestor is a spark-gap device, and can be installed anywhere. What is important, is that the wire is thick enough to withstand the lightning bolt and conduct the energy away from the building.
The bolt then partially travels down the line to your home.
So, it’s possible that these devices from Trip Lite have addition suppression devices, these ones seem to be sturdy.
I post the exact comment here.
It seems Mohan does not understand the difference between a comment and an Answer.
Here is a simplified AC power diagram.
Is the question then , "why buy a surge supressor, if the fuse alone protects the electronic circuits from a lightning bolt?".
“ … to protect building, lightning arrestor, is provided above building and directly connected to earth.”
These devices are installed between the “hot” and “neutral” and protective ground.
Edit 2024–10.
the problem then depends on "how fast does the fuse operate?".
When the current is 200% of the rated value , it will “go open” (the link metal melts) and protect the device.
But it can get overloaded, and no longer works.
Now when you have a certain ac resistance, then a current flows in a loop.
Upvotes:
2024–10–16 [ OO OLAOYE OYEBODE ]
Mohan forgets that a fuse is a one-time device, and needs to be replaced if it is tripped.
A fuse is a non-resetable over current circuit protector.
[old diagram got deleted by accident]
He then describes the function of a fuse.
There are two important concepts here.
One
[image of Common-mode choke]
And this is the problem alone. Is the power supply in the equipmemt designed with a lightning strike in mind? Some yes, others, no.
What is lightning?
Barnstars:
This is a high voltage low current spike that comes down the line because of the power poles being struck, and the voltage suppressors activating on the primary side of the transformer.
so, the loop of wire then, when put together with another loop reduces the ‘noise’ on a power line.
(Dc diagram shown, AC is similar).
OK, this is Mohan Rajaratnam’s definition of a Surge suppressor.
At one ohm, the resistor has a maximum of 1 watt power.
These are simplified answers to the original question, and does not change anything I wrote above.